Site Overlay

ADNOC HSE MANUAL PDF

II ADNOC HEALTH, SAFETY AND ENVIRONMENT A Library of HSE Systems , Programs and Procedures will be maintained by. ADNOC E&S Division. HSE Manual Description. VIKING Emergency Training Drills. VIKING Planned Equipment and Facilities Controls. ADNOC 10 Golden Rules of Safety (GOLDEN RULES OF work activities in line with requirements of respective HSE procedures & manuals.

Author: Yogal Mekinos
Country: Italy
Language: English (Spanish)
Genre: Travel
Published (Last): 17 October 2013
Pages: 139
PDF File Size: 7.87 Mb
ePub File Size: 10.7 Mb
ISBN: 786-7-80511-401-5
Downloads: 8040
Price: Free* [*Free Regsitration Required]
Uploader: Shakazil

This is particularly important in relation to supervisors whose responsibilities are often onerous and stressful. The company in control is called the Diving Contractor. Procedures, which eliminate blowback, etc.

ADNOC 10 Golden Rules of Safety

Procedures have been developed for the safe use of electricity under water, and any equipment used in a diving operation must comply with this guidance [Ref.

The range of vessels falling in to this category is substantial but some of the smaller or earlier generation vessels may still have some limitations which may well require careful consideration.

When diving from a dynamically positioned DP vessel, the responsible person on the DP control panel must inform the Diving Supervisor of any possible change in position-keeping ability as soon as it is known. Search the history of over billion web pages on the Internet. Surface-supplied diver certificates 1.

The entry must be dated and signed by the diver and countersigned by the Diving Supervisor. The dive plan must ensure that in a two-man bell, neither diver spends more than 6 hours out of the bell. The team size and composition must always be sufficient to enable the diving operation to be conducted safely and effectively.

The external pressure must be indicated to both the divers in the bell and the Diving Supervisor. Another diver must be on the surface with equipment suitable for intervention within the surface diving range. This will be recorded in the diving operations log.

  AQUENT SALARY SURVEY PDF

Full text of “ADNOC COPV 4 09( Ver 1)”

A dive plan that includes the use of such units must therefore also include safe operating procedures that are to be followed. If any USN type repetitive diving is conducted, then the Diving Supervisor must record in the diving operations log book his reason for allowing its use.

For example, umbilicals could be restricted in length, nanual electrical trip mechanisms or guards could be employed [Ref. Also see Manuwl 6. Allowances must also be made for leakage, wastage, and contingencies.

Does the Contractor make provision for documents to bridge his own emergency procedures and those of clients and sub- contractors? Prior to commencing the diving operations, all parties must be informed that: If this is by a separate generator, the positioning of this should be governed by the following factors: A suitable way to ensure the thoroughness of such sequences on each occasion is the use of pre-prepared checklists that require the relevant personnel to tick a box to demonstrate correct completion.

This may be, for example, where a diving team has been on standby, but not diving, for a number of hours before diving is needed. In the case of a rapid mobilization requirement does the Contractor have in place a procedure to ensure safety inspection and formal safety requirements are being followed?

This level of training will also require refresher training at regular intervals normally every three years that will comply with DMAC Training [Ref. Prior to mobilization it is recommended that a suitable person this may be the Diving Supervisor inspect the site and decide on the optimum location for the system. This authority does not extend to the duties of the Master of the vessel.

It must be designed with a chain or gate at the entry and exit point to prevent the divers falling out, and with suitable hand holds for the divers. It is the responsibility of every contractor to ensure that each diving system is supplied with the necessary documentation including at least the mnual The possession of the necessary qualification does not in itself demonstrate competence for any specific operation.

  AKTA KERAJAAN TEMPATAN 1976 AKTA 171 PDF

For saturation diving, the diver medic may be a team member on the surface but must be qualified to go under pressure in an emergency. Medical Examiner of Divers A doctor who is trained and competent to perform the annual assessment of fitness to mabual for divers. Canadian Category 3 Diver.

Lock Off Time The time at which a diving bell under pressure is disconnected from the compression chamber s on deck. The condition and integrity of the cable must be checked at six monthly intervals, or more frequently as circumstances dictate. Only vessels complying fully with all aspects such as number of reference systems, levels of redundancy, crew competence etc.

jQuery UniSlider

In such cases, extreme care must be taken and allowance must be made for the effects of fatigue. The Diving Supervisor with overall responsibility for the operation is the only person who can order the start of a dive, subject to appropriate work permits etc.

In saturation diving, the divers must be asked to undertake a bell run exceeding 8 hours from seal to seal. When was the last external audit? Is there any evidence that Contractors are vetting personnel to ensure they meet the required standards and possess the experience claimed in c.

Such measures must be part of a work control system such as a permit-to-work system, and could include mechanical isolation [Ref.